See clearly. Run steadily. Save significantly.
Roadway lighting is the first line of public safety. Nighttime driving, pedestrian movement, intersection recognition-every street light serves to reduce accident risk and improve traffic efficiency. Traditional roadway lighting has long relied on high-pressure sodium lamps and fixed timer switches: on at dusk, off at dawn, regardless of traffic volume or weather conditions. This one-size-fits-all approach carries three costs: wasted energy, severe lumen depreciation, and delayed fault detection.
Our outdoor roadway lighting systems are engineered to the rigorous standards of road applications-from light source, optics, and thermal management to structural protection. LED efficacy reaches 150-175 LM/W, paired with road-specific optics (Type II/III) to control glare while meeting illuminance uniformity requirements. IP66 ingress protection and IK08 impact resistance handle environments from urban arterials to highways. As a professional outdoor lighting manufacturer, we deliver complete systems-from luminaire to pole. One source. One warranty. One point of contact.
One-Line Value Proposition:
High efficacy. Low glare. Long lifespan. Roadway lighting built for safety and efficiency.
What Is Outdoor Roadway Lighting?
Definition
Outdoor roadway lighting is a lighting system installed along roadways or in median strips, projecting uniform, stable light onto the road surface via poles and luminaires. It improves nighttime visibility for drivers and pedestrians, reducing accident risk. Primary applications include urban arterials, secondary roads, branch roads, highways, ramps, and tunnel approach sections.
How Roadway Lighting Differs from General Outdoor Lighting
| Comparison | General Outdoor Lighting | Roadway Lighting |
|---|---|---|
| Core Objective | Area visibility | Road surface luminance and uniformity for driving safety |
| Optical Requirements | Broad spread | Type II/III road-specific optics, glare control |
| Mounting Height | 3-8m | 8-12m (urban roads), 12m+ (highways) |
| Standard Constraints | General lighting standards | Strict compliance with roadway lighting design codes (luminance, uniformity, glare limitation) |
| Environmental Requirements | Standard protection | IP66, IK08, wind resistance, surge protection |
Core Components
| Component | Function |
|---|---|
| LED Luminaire | 50W-300W, 150-175 LM/W efficacy, Type II/III road optics |
| Pole | Q235/Q345 steel, hot-dip galvanized + powder coated, 8-12m (higher optional) |
| Electrical Control | Timer/photocell switch, optional 0-10V/DALI dimming |
| Surge Protection | 10kV/20kV surge protection |
| Mounting Accessories | Brackets, clamps, cables |
Core Advantages
🔧 Advantage 1: High-Efficacy LED – 150-175 LM/W
Mainstream high-efficacy LED modules deliver 150-175 LM/W system efficacy. Compared to traditional high-pressure sodium (approx. 100-120 LM/W), this reduces power by 30%-50% at equivalent road surface illuminance-directly cutting electricity costs and electrical capacity requirements.
🔧 Advantage 2: Road-Specific Optics – Uniform Luminance, Controlled Glare
The core metric for roadway lighting is not "brightness"-it is road surface luminance uniformity and glare control. We offer Type II (medium angle, for standard roads) and Type III (narrower angle, for wider roads or highways) distributions, ensuring longitudinal and transverse uniformity compliance while controlling spill light through cut-off design, reducing glare toward drivers and light trespass to adjacent properties.
🔧 Advantage 3: IP66 + IK08 – Built for Demanding Outdoor Environments
IP66 ingress protection and IK08 impact resistance. Die-cast aluminum housing with powder coating resists heavy rain, high-pressure washing, salt spray, and industrial corrosion. Operating temperature range -40℃ to +55℃, suitable for climates from severe cold to high heat.
🔧 Advantage 4: Optimized Thermal Design – Slower Lumen Depreciation, Lower Maintenance Frequency
LED lifespan depends on thermal management. Light source and driver separation with finned heat sinks prevents heat stacking. System lifespan ≥50,000 hours, lumen depreciation under 5% at 3 years-reducing bucket truck trips and relamping costs.
🔧 Advantage 5: Optional Dimming Interface – Headroom for Future Upgrades
Standard timer/photocell control with reserved 0-10V/DALI dimming interface. Customers can deploy basic lighting within current budget and later add single-luminaire controllers or central management systems without replacing the luminaire itself.
Technical Specifications
Model Series
| Model | Power | Efficacy | Optics | Application |
|---|---|---|---|---|
| RL-50 | 50W | 150 LM/W | Type II | Branch roads, residential streets, pathways |
| RL-80 | 80W | 155 LM/W | Type II/III | Secondary roads, campus roads |
| RL-100 | 100W | 160 LM/W | Type II/III | Urban secondary arterials, mixed traffic roads |
| RL-150 | 150W | 165 LM/W | Type II/III | Urban arterials, four-lane roads |
| RL-200 | 200W | 170 LM/W | Type III | Arterials, expressway service roads |
| RL-300 | 300W | 175 LM/W | Type III | Highways, ramps, large interchanges |
Luminaire Specifications
| Parameter | Specification |
|---|---|
| LED Chip | Bridgelux / Philips / Cree (optional) |
| Luminous Efficacy | 150-175 LM/W |
| Color Temperature | 3000K / 4000K / 5000K / 5700K |
| CRI | ≥70 (standard) / ≥80 (optional) |
| Beam Angle | Type II / Type III (road-specific) |
| Ingress Protection | IP66 |
| Impact Resistance | IK08 |
| Operating Temperature | -40℃ to +55℃ |
| Lifespan | ≥50,000 hours |
| Surge Protection | 10kV (standard) / 20kV (optional) |
| Housing Material | Die-cast aluminum + powder coating |
Pole Specifications
| Parameter | Specification |
|---|---|
| Height | 8m / 10m / 12m (higher optional) |
| Material | Q235 / Q345 |
| Section Shape | Conical / Octagonal |
| Wall Thickness | 3mm-5mm (based on height and wind load) |
| Surface Treatment | Hot-dip galvanizing + powder coating |
| Corrosion Protection | 20+ years |
| Wind Resistance | Designed per project site wind load |
| Color Options | Any RAL color |
Electrical Specifications
| Parameter | Specification |
|---|---|
| Input Voltage | AC 100-277V / 50-60Hz |
| Power Factor | ≥0.95 |
| Total Harmonic Distortion | ≤15% |
| Control Method | Timer / Photocell / Manual (standard) |
| Dimming Interface | 0-10V / DALI (optional) |
| Surge Protection | 10kV / 20kV (optional) |
Applications
Application 1: Urban Arterials and Secondary Roads
Urban roads carry dense, mixed traffic with strict luminance and uniformity requirements. RL-100 to RL-200 with Type II optics deliver uniform road surface luminance at 10-12m mounting height; IP66 handles rainy urban environments.
Recommended: RL-100 to RL-200, 10m-12m poles, Type II/III optics.
Application 2: Highways and Expressways
High-speed roads require long visibility distances. Narrow-angle optics provide long-throw projection with low glare. RL-200 to RL-300 with Type III optics deliver continuous uniform illumination at 12m+ mounting height.
Recommended: RL-200 to RL-300, 12m poles, Type III optics, 20kV surge protection.
Application 3: Branch Roads and Campus Roads
Branch roads and campus roads carry lighter traffic with more pedestrians, requiring balanced road and pedestrian visual comfort. RL-50 to RL-80 with Type II optics provide cost-effective coverage at 8m mounting height.
Recommended: RL-50 to RL-80, 8m poles, Type II optics.
Application 4: Tunnel Approach Sections
Tunnel entrances and exits involve light-dark transitions requiring coordinated luminance with outside conditions. Dimmable models (0-10V/DALI interface) support output adjustment based on exterior luminance, reducing "black hole" and "white hole" effects.
Recommended: RL-80 to RL-150, 8m-10m poles, optional dimming interface.


why choose us

why choose our products
🏭 Professional Outdoor Lighting Manufacturer
| Our Advantage | What It Means |
|---|---|
| Complete system delivery | Luminaire, pole, electrical, and surge protection engineered as one system |
| Full in-house production | Pole fabrication, galvanizing, and luminaire assembly controlled in-house |
| Single source | One supplier, one warranty, one point of contact |
| Roadway expertise | We understand that uniformity and glare control-not raw brightness-are the core metrics |
✅ Quality Assurance
| Component | Quality Standard |
|---|---|
| LED Luminaire | 150-175 LM/W, ≥50,000 hours, IP66, IK08 |
| Pole | Q235/Q345, hot-dip galvanized + powder coated, 20+ years corrosion protection |
| Electrical System | Compliant with project country electrical safety standards, complete surge/earth protection |